___________________________________________________________________
 |                                                                 |
 |                             II DATA ITEM                        |
 |_________________________________________________________________|

 MEANING: Interdose Interval (II) data item for PREDPP
 CONTEXT: $INPUT record and NONMEM data set

 USAGE:
 $INPUT ... II ...

 DISCUSSION:
 II labels PREDPP's interdose interval (II) data item.   The  interdose
 interval  data item is optional.  In a dose or reset-dose event record
 it gives the time between  implied  or  additional  doses  (i.e.,  for
 repeated doses with a given period, the II data item is this period).

 For a steady-state infusion (AMT=0; RATE>0), II should be 0.

 For other steady-state doses, II should  be  a  positive  number.   II
 gives the time between implied doses.

 For non-steady-state doses, II should be a positive number if and only
 if the ADDL data item is a positive number.  II gives the time between
 additional doses.

 For observation, other-type, and reset event  records,  II  should  be
 zero.

 The units of II should be consistent with those of TIME.

 Any II value in the NM-TRAN data set that contains  a  colon  (:)   is
 assumed to be a clock time (hh:min) and NM-TRAN converts it (to hh.fr)
 as in the first example:

      NM-TRAN data set   NONMEM data set
      II                 II
      ----               ----
      1:30               1.50
      1.30               1.30

 The $DATA record may include the option  TRANSLATE=(II/24),  in  which
 case  all  interdose  interval  data  items (obtained after clock time
 conversion) are divided by 24.  (See $data).

 (See exogenous supplementation example).

REFERENCES: Guide VI Section V.G
REFERENCES: Guide IV Section V.B


  
Go to main index.
  