___________________________________________________________________
| |
| SCALING PARAMETER |
|_________________________________________________________________|
MEANING: Scaling (S) parameter for PREDPP
CONTEXT: Additional PK Parameters
USAGE:
$PK
S2= ....
DISCUSSION:
Scaling parameters are used with PREDPP. They are optional additional
PK parameters. With NM-TRAN, they are symbolized in the $PK block by
reserved variables Sn, where n is the compartment number to which the
parameter applies.
For each observation (or at any time other than an observation time
for which a prediction is needed), PREDPP computes a prediction avail-
able to the ERROR routine. Associated with each observation is an
observation compartment. The amount A in the observation compartment
at the time of observation, divided by the value of a parameter S, is
used as the prediction. The parameter S is called a scaling parameter.
There is one such parameter associated with every compartment of the
kinetic model (including the output compartment).
Scaling parameters are optional in the sense that scaling parameters
associated with compartments with which predictions are not needed may
be ignored. The values of scaling parameters that are not computed in
PK are always understood to be 1.
A scaling parameter is computed by the PK routine using, if needed,
information in the event record.
(See cmt, pcmt, pk, $pk, default_compartment).
REFERENCES: Guide IV Section V.C.5
REFERENCES: Guide V Section 3.2.2, 7.4.3
REFERENCES: Guide VI Section III.F.1, V.H
Go to main index.